Petromium Tools / Formula set KICK-TOL-001

Kick Tolerance & MAASP

Static initial shut-in screening envelope · explicit pressure-limit hierarchy· V2.0

Context
Units
Stored only in this browser · tap any field unit for instant conversion

Visual screening model

Static pressure and influx envelope

Weak-point and influx context

Casing shoe · pressure reference Rig surface / annular gauge

01,0002,0003,0004,0005,0006,0007,0008,0009,00010,000TVD (ft)SURFACETD 10,000 ftCasing shoe 4,000 ftMAASP874 psiTD ANNULAR356 psiMUD 10 ppgKICK INTENSITY 0.5 ppgMARGIN 518 psiCASEDKICK SOURCESHALE

Kick-tolerance envelope

Maximum allowable influx versus kick intensity

00.40.71.11.51.8197.2157.8118.378.939.40Kick intensity (ppg equivalent)Maximum influx (bbl)OPERATING POINT · 0.5 ppg · 128.2 bbl · Casing shoe formation MAASPSafe regionBoundary

Selected ceiling

873.6 psi

Max static volume

128.24 bbl

Max static height

1,534 ft

Zero-volume KTF

1.68 ppg

Check margin

517.9 psi

Review · not an approval

Governing limit

Pressure source

Casing shoe formation MAASP

Formation MAASP

873.6 psi

Selected intensity pressure

260 psi

Remaining static budget

613.6 psi

The minimum comparison uses only sources you explicitly enable. It does not approve a weak point, derive equipment derating, or prove circulation tolerance.

Entered choices stay separate

Static screening worksheet

Weak-point basis

Basis

Selected screening point

Influx fluid type is never inferred. Enter the screening gradient explicitly. Subsea CLFL is displayed only as a separate manifold-reference comparison.

Pressure-limit hierarchy

All enabled values must share the declared pressure reference.

873.6 psi · exact SI 872.7 psi

Bottom-up annular geometry

Row 1 is the bottom segment. Measured capacity overrides cylindrical capacity with visible provenance.

01

Selected capacity

0.0836 bbl/ft

measured

Calculation complete

Calculation audit

0 warnings

Max density

14.2 ppg

Selected KTF

1.68 ppg

Check pressure

355.7 psi

Check margin

517.9 psi

Calculation observations

STATIC_INITIAL_SHUT_IN_ONLY

Static initial shut-in screening only. This result does not demonstrate that an influx can be circulated out without exceeding MAASP.

Operational use warning: verify the controlled well program, weak-point/test interpretation, pressure-reference consistency, fluid and influx data, geometry, working limits, deratings, and contingencies. This static screen does not demonstrate circulation tolerance.
KICK-TOL-001 v1.0.0 · SPE / IADC static envelope basis · API RP 59 landscapeReference example loaded — replace every value with verified well data.