Petromium Tools / Formula set TRIP-TALLY-001

Trip / Tally Displacement

Planned-versus-observed trip monitoring · connection-aware string tally · V2.0

Context
Units
Stored only in this browser · tap any field unit for quick conversion

Trip-tank displacement path

Pull out of hole · surface

String position and trip tank

pooh · 10 units · current string depth

0900MD (ft)SURFACETD 900 ftDrillpipe stands 01-10 · 10 drillpipeString movement directionSTRING END 900 ft MDPLAN / OBSERVED · bblEXPECTED / OBSERVED28.6 / bblΔ bblHOLE TD IS NOT INFERRED · STRING END IS SHOWN AT CALCULATED TALLY DEPTH

Cumulative fill comparison

Expected versus observed volume over moved segments

00.20.40.60.817.25.74.32.91.40Tally segmentCumulative volume (bbl)TOLERANCE ±0.5 bbl · OBSERVED DATA NOT ENTEREDExpectedObserved

Expected volume

6.416 bbl

Observed volume

Not entered

Expected strokes

64.2 strokes

Moved length

900 ft

Planned tank level

28.58 bbl

Review · not a diagnosis

Trip monitoring snapshot

Observed − expected

Not entered

Metal displacement

6.416 bbl

Closed-end displacement

22.27 bbl

Unfilled pressure reduction

28.4 psi

Observed volume is never inferred from the planned value. A variance label is a review cue only; it is not a kick/loss diagnosis or an operational instruction.

Explicit geometry · measured volume stays separate

Trip sheet and physical tally

Operation configuration

Direction
Condition
Declared model boundary: static cylindrical displacement and free-surface fall only. Surge/swab, compressibility, gas, ballooning, losses, influx, vessel/riser motion, sensor lag, transfers, and dynamic tank response are excluded.

Tally rows

Enter stands, joints, or assemblies in movement order. Connection geometry is calculated separately.

01

Row result

Plan 6.416 bblActual Flag Not enteredTank 28.58 bbl

Calculation complete

Calculation audit

0 warnings

Expected

6.416 bbl

Observed

Joints

30

Strokes

64.2

Calculation observations

STATIC_DISPLACEMENT_MODEL

Static cylindrical displacement only. Surge/swab, compressibility, ballooning, losses, influx, gas migration, riser motion, sensor lag, transfers, and dynamic trip-tank response are excluded.

Operational use warning: verify physical tally, connection dimensions, end condition, pump and tank calibration, line-up, sensor resolution, and transfers. Treat unexplained variance under the approved program; this worksheet does not diagnose influx or loss.
TRIP-TALLY-001 v1.0.0 · SPE / IADC geometry family · API RP 59 landscapeReference example loaded — replace every value with verified job data.